为解决往复压缩机出口管系振动幅值超标的问题,通过对该压缩机组进行现场振动检测和数据采集,分析了引起振动的原因,制定了解决方案。整改后的压缩机出口管系振动幅值达到设计标准,现场使用效果良好。
為解決往複壓縮機齣口管繫振動幅值超標的問題,通過對該壓縮機組進行現場振動檢測和數據採集,分析瞭引起振動的原因,製定瞭解決方案。整改後的壓縮機齣口管繫振動幅值達到設計標準,現場使用效果良好。
위해결왕복압축궤출구관계진동폭치초표적문제,통과대해압축궤조진행현장진동검측화수거채집,분석료인기진동적원인,제정료해결방안。정개후적압축궤출구관계진동폭치체도설계표준,현장사용효과량호。
In order to solve the problem of vibration amplitude exceeds the standard requirement in reciprocating compressor outlet pipeline, through the field vibration monitoring and data collection of the compressor, the reasons causing the vibration are analyzed and the solutions are developed. The vibration amplitude of compressor outlet pipeline after the rectification reached the design stan-dards, and the effect on site is good.