李心霞%公茂盛%韩庆华%谢礼立
李心霞%公茂盛%韓慶華%謝禮立
리심하%공무성%한경화%사례립
RC frame structure%strong column-weak beam%limit value of column-beam relative factor%moment magnification factor at column end
Most reinforced concrete(RC)frame structures did not achieve the “strong column-weak beam” failure mode in recent big earthquakes, resulting in a large number of casualties and significant property loss. To deal with this serious problem, a new column-beam relative factor was proposed to characterize the relative yield situation of column ends and beam ends. By limiting the column-beam relative factor, RC frame structures could achieve the“strong column-weak beam” failure mode under the excitation of strong ground motions. The limit values of col-umn-beam relative factor were calculated, analyzed and verified by using structural simulation models for corner columns in the bottom story of structures, which are destroyed most seriously in earthquakes. The results show that the limit values should be analyzed under bi-directional ground motion and with different axial compression ratios of columns. The peak ground acceleration(PGA)of ground motions has no significant effect on the limit values, while the type of strong ground motions has a significant effect on the limit values.